Add To Enquiry

Domestic Series

CYBER UPS

Features:

  1. 15% Extra Back - up
  2. Wide charging Window ( 110VAC to 280VAC)
  3. Compact Design & Light Weight
  4. 20%- 25 % Saving in Electricity
  5. Compatibility With Generator
  6. OSCRCTM Technology Based Charger
  7. External DC Fuse (Easy to Replace)
  8. Capable of Charging/Recovering Deep-Discharged Battery
  9. Zero Battery Consumption in ‘Switch Off ’ & ‘Mains Off ‘ Conditions
  10. Pure Sinewave even with Computer & Compact Fluorescent Lamp (CFL) Load
  11. Lower Battery Discharge as compared to a conventional Home UPS/Inverter

Technical Specifications*

DESCRIPTION 650VA 850VA 1450VA
INVERTER MODE
Output Voltage At No Load 220 VAC ± 7 VAC
Output Frequency 50.0 Hz ± 1.0Hz
Output Wave Form Sinewave
Nominal Battery Voltage 12 VDC 24 VDC
MAX. NO LOAD CURRENT @ FULLY CHARGED BATTERY 1.7A 1.4A
BATTERY LOW ALARM 10.6 ± 2 VDC 21.2 ± 0.2 VDC
BATTERY LOW PROTECTION 10.4 ± 2 VDC 20.8 ± 0.2 VDC
EFFICIENCY > 85% > 85%
NO LOAD CURRENT @ SWITCH OFF/MAINS OFF 0A
THD ( TOTAL HORMONIC DISTORTION ) < = 2.5% @ resistive
UPS MODE
INPUT VOLTAGE RANGE 180 to 270 VAC ± 10 VAC
CHANGEOVER TIME MAXIMUM < = 10ms
NORMAL MODE
INPUT VOLTAGE RANGE 90 to 280 VAC ± 10 VAC
INPUT VOLTAGE RANGE FOR CHARGING 90 to 280V ± 10 VAC
MAXIMUM CHANGE OVER TIME < = 10ms
CHARGING MODE
CHARGING CURRENT @ 220VAC (NC) 8A +/- 1A 10A +/- 1A
CHARGING CURRENT @ 220VAC (HC) 11A +/- 1A 13A +/- 1A
BOOST CHARGING VOLTAGE 14.2 ± 0.2 VDC 28.4 ± 0.2 VDC
FLOAT CHARGING VOLTAGE 13.7 ± 0.2 VDC 27.4 ± 0.2 VDC
PROTECTIONS
Protection WIRING FAULT, BATTERY VOLTAGE LOW (4 AUTO RETRIES), OVER LOAD (6 AUTO RETRIES)
BATTERY OVER CHARGE, OVER TEMPERATURE, SHORT CIRCUIT (ONE RETRY), BATTERY DEEP DISCHARGE PROTECTION
DISPLAYS
LCD Display Mains on, Main Voltage, Output Voltage UPS ON / OFF
Short Circut, Overload, Battery Low, Load %
Mains ON / OFF, Battery Charging / Charged / Battery Low
 
WEIGHT AND DIMENSIONS
With Packaging LXWXH in mm 350x290x135 365x320x125
Without Packaging WXDXH in mm 310x215x85 310x240x85
Net Weight 3.2Kg 3.9Kg
Gross Weight 3.9Kg 4.5Kg
GENERAL
Communication 4 PIN Serial interface for calibration of various parameters
Operating Temprature range 0 Deg to 45 Deg
Relative Humidity 0-90% Non Condensing
Relative Humidity 0-90% Non Condensing

Note : The charging currunt can be increased / decreased using the unieque and first-in-class On Site Charging Rate Control (OSCRS) features


Load Chart * (Take from cyber UPS PDF)

Load 650VA/12V 850VA/12V 1450VA/12V
T.V 1 - - 1 - - 1 - -
Tube Light 4 4 - 6 5 - 10 8 -
Fan 3 4 - 4 5 - 7 9 -
Computers** - - 4 - - 5 - - 10

Note

The Charging Current can be increased / decreased using the unique and "first-in- class" On Site Charging Rate Control OSCRCTM features. **For Computer with 14" TFT monitors